24VAC SENSOR COM 1 2 3 4 5 6
Level
Fasten screw through one of the
pre-formed mounting holes.
24VAC SENSOR COM 1 2 3 4 5 6
Do not connect to power
source until after wiring
valves to timer.
TIMER
QUICK START
GUIDE
PN 57874-50 rB
p 801 295 9820
f 801 951 5815
www.fluid-studio.net
1065 South 500 West
Bountiful, Utah 84010
proof no: 4
date: 09.13.11
des: SM
client: Orbit
sku: 57874
upc: NA
file name: 57874-50 rB.indd
software: InDesign CS5
colors
additional instructions:
· Font sizes cannot be smaller than 7 pt.
· Translation Approval code: LB682594
fold color
non printing
PMS
????
PMS
????
color
non printing
PMS
????
Registration
K
Printers are responsible for
meeting print production
requirements. Any changes
must be approved by the
client and Fluid Studio.
printed piece must meet
designated specifications
on this form.
dimensions:
flat: w: 28" h: 14"
finished: w 28" d: " h 14"
© 2007 Fluid Studio. This
work is the property of Fluid
Studio, and cannot be used,
reproduced or distributed
in any way without their
express permission.
1. SELECT LOCATION
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Indoor
Clean, dry, and out of direct sunlight.
A
F
G
H
B
C
D
E
ENTER - To confirm a new setting
MANUAL - To water manually
CLEAR - To clear a setting
PROGRAM - to switch between
programs - A and B
ARROW [ ] - To skip to the next
setting / watering station or move to
other programs/settings
ARROW [ ] - To go back to the
previous setting / watering station or
move to other programs/settings
RAIN DELAY - To pause operation
for 24-72 hours due to rain or other
factors
[
+
] To increase a numeric setting
[
-
] To decrease a numeric setting
MANUAL
Button Function:
AUTO - Watering mode
SET CLOCK - Set calendar and clock time
SET DATE - Year, Month, and Day
START TIME - Set time to begin watering
RUN TIME - Set watering duration for
each station
HOW OFTEN - Set frequency of
watering days
OFF - Turn all stations off
Dial Position Function:
A
B
C
F
D
E
G
H
Reset
Shroud
cover
attachment
5. CONNECT TO
ELECTRICAL POWER
24VAC SENSOR COM 1 2 3 4 5 6
4. CONNECT VALVE WIRE
TO TERMINAL
Station 1
Strip wire
Push in wire and
tighten screw
Only connect one valve to
each terminal (station).
7. PROGRAM TIMER
Turn dial to SET DATE and enter current date
(+/-) (enter or arrows will advance).
Set Current Time
(e.g. pacific,
mountain standard)
A
Turn dial to SET CLOCK enter current time (+/-).
Set Date
B
SET
DATE
C
Watering
Start Time
Turn dial to START TIME and to enter the time to begin
watering (+/-). Important: Only set one start time per
station unless you want to water multiple times per day.
D
Set Watering Duration
for Each Station
Turn dial to RUN TIME enter the watering duration (+/- ) for
each station (enter or arrow to move between stations).
E
Set Watering
Days or Interval
Turn dial to HOW OFTEN to select watering days
(arrows to move between selections and enter to select).
Set Auto Mode
F
Turn dial to AUTOCongratulations, you have programmed your timer!
(See page 9 of manual for detailed instructions on programming.)
Keyhole
Pre-formed
mounting holes
No. 8 Screw
Wall
1/8"
2. MOUNT TIMER
Use included mounting template to
mark screw locations.
Hang timer on screw using keyhole.
To
Timer
Wire Nut
Solenoid
Common Wire
Valve
Connect one of the two wires from each valve to the
common wire leading to the timer (usually white).
Connect the other wire from each valve to one of the
colored wires leading to the timer.
3. CONNECT SPRINKLER
VALVES TO TIMER WIRES
6. ACTIVATE BATTERY
Remove plastic
strip to activate
battery.
One Lithium CR2032 battery (included) is
required to retain the program in memory
during power loss. Annual replacement is
recommended.
Remove the plastic strip to activate the
pre-installed battery.
Battery
REQUIRED TOOLS:
Phillips Screwdriver
Wire Strippers
Manual Watering
G
Press MANUAL—Program will start in 5 seconds.
Attach power
connector to 24VAC
plug on the timer
wiring terminal.
Note: The quick start guide is intended to help you
get up and running with your new timer. It includes
basic installation and programming help. For more
detailed and advanced instruction, please refer to
the included timer manual.
I
I
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - QUICK START

24VAC SENSOR COM 1 2 3 4 5 6LevelFasten screw through one of thepre-formed mounting holes.24VAC SENSOR COM 1 2

Seite 2 - TEMPORIZADOR

24VAC SENSOR COM 1 2 3 4 5 6No conecte al suministro de electricidad hasta haber cableado las válvulas al temporizador.GUÍ

Kommentare zu diesen Handbüchern

Keine Kommentare